Belgian authorisations from the BIPT frequency table accompanying the decision of 24 May 2019.

IBPT/BIPT: Freq-FR.pdf

Band Frequencies (MHz) Permitted emission classes Maximum power (8) Status / BIPT notes
2200 m 0.1357-0.1378 All emission classes 1 W ERP S
630 m 0.472-0.479 All emission classes 5 W EIRP S
600 m 0.501-0.504 A1A 5 W EIRP S (6)
160 m 1.810-1.830 All emission classes 1500 W S (1)
160 m 1.830-1.850 All emission classes 1500 W PEX
160 m 1.850-2.000 All emission classes 150 W S
80 m 3.500-3.800 All emission classes 1500 W P
60 m 5.3515-5.3665 All emission classes 15 W ERP S
40 m 7.000-7.100 All emission classes 1500 W PEX (2)
40 m 7.100-7.200 All emission classes 1500 W S
30 m 10.100-10.150 All emission classes 1500 W S
20 m 14.000-14.350 All emission classes 1500 W PEX (2)
17 m 18.068-18.168 All emission classes 1500 W PEX (2)
15 m 21.000-21.450 All emission classes 1500 W PEX (2)
12 m 24.890-24.990 All emission classes 1500 W PEX (2)
10 m 28.000-29.700 All emission classes 1500 W PEX (2)
6 m 50.000-52.000 All emission classes 200 W S
4 m 69.950 All emission classes 10 W EIRP S (7)
4 m 70.1125-70.4125 All emission classes 50 W S
2 m 144.000-146.000 All emission classes 1500 W PEX (2)
70 cm 430.000-433.050 All emission classes 1500 W P
70 cm 433.050-434.790 All emission classes 200 W P (9)
70 cm 434.790-440.000 All emission classes 1500 W P (3)
23 cm 1240.000-1270.000 All emission classes 200 W S
23 cm 1270.000-1300.000 All emission classes 200 W S (3) (4) (10)
13 cm 2300.000-2450.000 All emission classes 200 W S (3) (5)
6 cm 5650.000-5725.000 All emission classes 200 W S (3) (4)
6 cm 5725.000-5850.000 All emission classes 200 W S (2) (5)
3 cm 10000.000-10450.000 All emission classes 200 W S
3 cm 10450.000-10500.000 All emission classes 200 W S (2)
1.2 cm 24000.000-24050.000 All emission classes 200 W PEX (2) (5)
1.2 cm 24050.000-24250.000 All emission classes 200 W S
6 mm 47000.000-47200.000 All emission classes 200 W PEX (2)
4 mm 75500.000-76000.000 All emission classes 200 W P (2)
4 mm 76000.000-81000.000 All emission classes 200 W S (2)
2.5 mm 122250.000-123000.000 All emission classes 200 W S (2)
2 mm 142000.000-144000.000 All emission classes 200 W PEX (2)
2 mm 144000.000-149000.000 All emission classes 200 W S (2)
1.2 mm 241000.000-248000.000 All emission classes 200 W S (2)
1.2 mm 248000.000-250000.000 All emission classes 200 W PEX (2)

P: primary; PEX: primary and exclusive; S: secondary. A secondary service must not interfere with primary services and cannot claim protection from their interference.

The BIPT table’s units are retained: W; ERP = effective radiated power (p.a.r.); EIRP = equivalent isotropically radiated power (p.i.r.e.).